Furnace Vent Pipe Height Above Roof

Understanding The 10 Foot 2 Foot 3 Foot Rule How To Determine The Chimney Height Of Class A Solid Fuel Pipe Above The Roofline

Understanding The 10 Foot 2 Foot 3 Foot Rule How To Determine The Chimney Height Of Class A Solid Fuel Pipe Above The Roofline

Mastering Roof Inspections Roof Penetrations Part 3 Internachi

Mastering Roof Inspections Roof Penetrations Part 3 Internachi

Plumbing Faucet Repair Plumbing Vent Height Above Roof

Plumbing Faucet Repair Plumbing Vent Height Above Roof

Vent Pipe Termination Distance Over Roof Terry Love Plumbing Advice Remodel Diy Professional Forum

Vent Pipe Termination Distance Over Roof Terry Love Plumbing Advice Remodel Diy Professional Forum

Gas Vents Upcodes

Gas Vents Upcodes

Gas Water Heater Vent Codes Standards

Gas Water Heater Vent Codes Standards

Gas Water Heater Vent Codes Standards

The photo shows a b vent from a fan assisted furnace flue on a steep sloped hip roof.

Furnace vent pipe height above roof.

Roof pitch rise run in inches. Any moisture entering this pipe will be drained off before it reaches the furnace by components designed to divert condensation so it doesn t need to be protected. Single wall metal pipe shall terminate at least 5 feet 1524 mm in vertical height above the highest connected equipment draft hood outlet or flue collar. Minimum height above the roof surface 1 flat to 7 12.

2 5 feet above the roof surface. 2 0 feet above the roof surface. General rule the chimney should not be outside a window or other house opening. Table of rooftop chimney clearances for metal b vent chimneys flues.

2 run the vent pipe up through the roof and install a metal or pvc flashing collar over it. 1 5 feet above the roof surface. Single wall metal pipe shall extend at least 2 feet 610 mm above the highest point where it passes through a roof of a building and at least 2 feet 610 mm higher than any portion of a. I know about the 2 feet taller than the roof when a vertical wall is within 8 feet as in illustrated in my code check books.

If the previous calculation results in the required height of 64 inches we can see that the top of the pipe will not rise above the roof peak but would still meet the requirements of the rule. However i have searched archives on this and another site and have come across various interpretations of the height requirement. Water heater installed close to the roof framing would need at least 5 long vertical vent pipe single wall vent pipe requires minimum 6 of clearance to combustible materials. The top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.

Roof pitch rise run in inchesminimum height flat to 7 12 1 0 foot above the roof surface 7 12 to 8 12 1 5 feet above the roof surface 8 12 to 9 12 2 0 feet above the roof surface. For 18 feet of run you would have a rise of 72 inches. For the next example you have a shorter chimney height. If the pipe is farther than 10 feet from the roof.

Put the roof opening directly above the exhaust opening on the furnace. Vent caps 12 and smaller may terminate a distance above the roof if 8 feet or more away from a vertical surface as follows. Chimney chimney flue must terminate min. 1 0 foot above the roof surface 1 7 12 to 8 12.

Charleston Home Inspector Discusses Gas Vents Blue Palmetto Home Inspection

Charleston Home Inspector Discusses Gas Vents Blue Palmetto Home Inspection

Chimney Height Clearance Code Q A Faqs Set No 2